AUTONEST VCSettings · Peace of mind

Broke a setting? Put it back.

2026-09-09 · 4 min read

Values that differ by company — plate sizes, the thicknesses you stock, flange defaults — are yours to edit. Which means you can also change them wrongly. One bad number, one calculation, and the thickness comes out strange — it happens. For that, AUTONEST VC has three layers: block, keep, put back.

Edit in [Data settings] plates · thicknesses · flanges … Blocked before saving wrong-format lines flagged Backups kept on save · on calculation [Restore DB] pick a point in time Your values stay after automatic updates and after a reinstall They could be left open to edit because they can always be put back
Block, keep, put back — why you can edit the data settings without worrying

Where do I edit them?

In the [Data settings] tab in the middle of the app. Pick an item in the list on the left, edit the table on the right, and save. Plate sizes · plate thicknesses · jacket closure and clearance · flange thickness · bolt holes · washers · nozzle thickness and pads · sight glass · relief devices · part defaults all live here.

These lists change the result. A required thickness of 6.3 is rounded up to a thickness on the list, so if 7 is not on the list it becomes 8. The plate-size list is the range that standard-plate matching (SNAP) and the order list work within. Matching them to the plates and thicknesses actually in your stock is the first thing to do.

Why a wrong edit doesn't show right away

If a line goes missing from a list, the calculation does not stop. It runs normally within what is left, and only the result changes. Say you accidentally delete the line that reads 7 in the thickness list. A plate that needs 6.3 is then confirmed at 8, not 7. No error, just one step thicker.

So if something is "suddenly thicker" or "no longer matches a standard plate", suspect the data settings before the calculation.

1. Blocked before saving

If a number column gets text, or an ON/OFF column gets something else, the app tells you which line before it saves. Fix that line and save again. This stops a wrong-format file from being saved and read as an odd value by the calculation.

2. Kept on every save and every calculation

3. Pick a point in time with [Restore DB]

Press [Restore DB] at the bottom of the app and a list of backup times appears. Pick one and the DB goes back to that point, applied from the next calculation. You never have to find which line you got wrong — just pick a point when things were right.

What about updates and reinstalls?

Values you changed in Data settings stay as they are after automatic updates. When a new version adds items, only the new items are added.

Even if you uninstall and reinstall the program, the backups remain outside the install folder (Documents\Autonest\VC\DB_Backup). On the first calculation after reinstalling, the app asks once whether to restore the DB you used before. Choose [Yes] and you carry on with your old lists.

So you can edit without worrying

Company values are open to edit because they were made recoverable first. If there were no way back, they could not have been left open.

Add a line to the thickness list, change a plate width — and if the result looks wrong, pick a good point under [Restore DB]. If it still feels tangled, tell us via [Account] → Report a bug / suggestion or by e-mail (autonestk@gmail.com).

What you can change in Data settings — on video, on the real screen.

Watch: Data settings →