AUTONEST VCFeatures · Jacket

The jacket rises to the working level by itself

2026-09-09 · 5 min read

Jacket length is an awkward number to pick. Too short and the top of the liquid is left out of the heat exchange; too long and you are buying plate for nothing and running into the fittings above. AUTONEST VC leaves it blank and sets it to the working liquid level automatically, and if you enter a value, that value wins — except that a physically impossible value is adjusted to one that works, and you are told.

working level jacket top = liquid level Left blank — automatic working volume → level → jacket length Entered — that value wins one cell: JACKET_TL-WL Impossible — adjusted + notice above shell − 50 · below 50 Drawing · report · material list one jacket length in all three any adjustment shows as one line in the run log
The level is the default, the user is the exception, and the limits are kept by the program

Leave it blank and it follows the level

Leave the jacket-length cell (JACKET_TL-WL) empty and the length is worked back from the working volume. If a target capacity was given, that is the starting point; otherwise it is the total volume times the working ratio.

The liquid is taken to fill the bottom head first and the cylinder with what is left, which gives the liquid level. The jacket top is set to that height — allowing for the jacket cylinder starting a little below the inner cylinder.

So the jacket goes exactly as far as the liquid does. Above that it is plate that does no heat exchange; below it would be liquid with no jacket.

Enter a value and that value wins

Sometimes the jacket length has to be set to suit an installation or an existing vessel. Then you put a number in JACKET_TL-WL — the straight length of the jacket cylinder, from the bottom-head tangent line up to the closure.

An entered value takes priority even in capacity mode. Jacket length is a separate dimension from the inner vessel's capacity, so it does not conflict with the target. Stop it below the level or run it higher — the user's value stands.

Impossible values are adjusted to possible ones

What it will not do is keep a value that cannot physically exist.

When an adjustment happens, one line appears in the run log — "jacket length exceeds the physical limit of 635 mm, adjusted to 635 mm". Nothing is changed silently.

Give it room for a fitting, and that comes before the level

A jacketed vessel with a flange has one more constraint. Between the flange underside and the jacket closure there has to be room to weld a hinge or a clamp. Raise the jacket to the liquid level alone and it can eat that space.

So the basic settings carry one cell for the closure-to-flange gap (CLO-F/BTM). The default is 50 mm; give more if the fitting is bigger. With that value in place the jacket never intrudes on that distance.

The rule is simple — take the length set by the liquid level and the length that respects the fitting gap, and use the shorter one. Normally the level decides. But the moment the level would climb into the fitting's space, the gap decides instead. The jacket gives up a little rather than lose the hinge.

A few millimetres of heat exchange matter less than not being able to mount the hinge.

The same number on drawing and report

Whichever rule decided it, the final jacket length is one value. The jacket length on the drawing, in the report and on the jacket plate in the material list is the same number. Whether it was automatic, entered or adjusted is recorded in the run log, and every output is lined up to that one value.

In the 3-tonne jacketed run the jacket length of 1524 was measured on both the report and the drawing.

Watch: the 3-tonne jacketed tank run →