The flange is the part of a pressure vessel that takes the most handling. Shape, gasket, connection, bolts and thickness are all tied together — change one and the others move. AUTONEST VC is built so that choosing a few types brings the drawing, the thickness, the bolt count and the CAD geometry along with it.
On one row of the Flanges tab you set type, shape, connection, gasket and groove. Loose flange or bolted cover; half or full slip-on; bolt or clamp; O-ring, FF or RF; groove or none. These are decisions the shop has to make anyway, and nothing beyond them is asked.
Thickness, bolt count and outside diameter are not chosen — they come out.
The flange calculation sheet carries a section drawing. But a half slip-on with an O-ring, bolts and a groove looks nothing like a full slip-on with an FF gasket and a clamp. One picture cannot cover both.
So the sheet holds 13 pictures, one per combination. On a run, the one matching your choice is kept and the other twelve are deleted. A reviewer opening the report sees exactly that flange's section and nothing else. Nobody says "this picture isn't ours".
Flange required thickness has one awkward property: it depends on the thickness itself. A thicker flange changes the lever arm the bolts pull on, and that changes what is required. It is not a one-shot calculation.
So the engine tries the standard list from the bottom. Put in 8, calculate, not enough — try 10, then 12 — and the first one that passes is the answer. Corrosion allowance and groove depth are already inside.
The list is your company's. The default runs 8 to 70 in twenty steps, and if you replace it with the sizes you can actually get, it chooses only from those. If even the top of the list fails it shows NOT OK. It never passes quietly, and it never reaches outside the list on its own.
How many bolts also has to be decided. From the pressure and gasket conditions the engine computes the required bolt count and writes it into the sheet. The outside diameter is then settled around where those bolts and their washers sit. Change one bolt size and the count and diameter follow.
A bolted cover (flat plate) carries load in a different way from a loose flange. Bending under pressure and seating the gasket are checked separately, and the thickness that satisfies both is taken. It gets its own calculation sheet.
The option that steps up the parent plate to remove a nozzle pad applies to covers as well: the cover thickness is tried one step up the list, and if that still fails it is put back and the pad is added.
When the calculation finishes the flange is drawn in the drawing. Not just the thickness — how far it seats into the shell is drawn from the same values. Flange thickness in the report, on the drawing and in the material list is one number in all three, because nothing was copied across by hand.
Sometimes the flange is already in stock, or the customer has specified the thickness. In Manual mode you enter that thickness and it is judged, not raised. Pass or NOT OK. It does not quietly change the thickness and then say "fine".
See how a loose flange and a bolted cover actually come out differently in the six-types video.