AUTONEST VC ›

Pressure Vessel Strength Calculation Report Sample — Single Vacuum · Jacketed 2,000 L (Notice No. 2025-61)

Two hypothetical cases (A: single tank under vacuum, 2,000 L · B: jacketed tank, 2,000 L, jacket design pressure 0.5 MPa · design temperature 160 °C) calculated with AUTONEST VC: the report PDFs, required and used thickness with the result for each part, and an approximate cross-check of the external-pressure chart values — published as they are.

Calculation basis: “Standard for Inspection and Inspection Exemption of Heat-Using Equipment” (unofficial English translation; MCEE Notice No. 2025-61, Korea, partially amended 18 Dec 2025) — the Korea Energy Agency inspection-target basis. All figures are taken from the report PDFs below. The reports are in Korean.

Design conditions

ItemA · Single, vacuumB · Jacketed
TypeSingle (with manhole)Jacketed (with manhole)
Working capacity2,000 L (2 m³)2,000 L (2 m³)
Shell (inner vessel) materialA240-316LA240-316L
Shell ID × length1,345 × 1,480 mm1,345 × 1,480 mm
Heads (top · bottom)10% torispherical (dished)10% torispherical (dished)
Inner design pressure0.3 MPa · vacuum −0.1 MPa0.3 MPa · vacuum −0.1 MPa
Inner design temperature120 °C120 °C
Inner external design pressure0.1 MPa (vacuum)0.6 MPa (jacket 0.5 + vacuum 0.1)
External-pressure design temperature120 °C160 °C
Jacket material—A240-304
Jacket ID · length—1,455 mm · 1,245 mm
Jacket design pressure · temperature—0.5 MPa · 160 °C
Corrosion allowance0.0 mm0.0 mm
Joint efficiency (shell / head)0.95 / 1.00.95 / 1.0
Hydrostatic test pressure0.51 MPainner 0.51 MPa · jacket 0.85 MPa

Key results

Required thickness is the minimum (calculated) thickness in the report. The value in brackets after the used thickness is the actual thickness after plate tolerance (and forming thinning for heads); that value is compared with the required thickness. For external pressure, the allowable external pressure is calculated from the used thickness and compared with the external design pressure.

AA · Single, vacuum (inner external pressure 0.1 MPa)

PartClauseRequiredUsedResult
Shell · internal[30.1.1] cylindrical shell2.00 mm6 mm (5.75)OK
Shell · external[30.3] · [Fig. 30.5]allowable 0.17 MPa ≥ design 0.1 MPa6 mmOK
Top head · internal[31.3.1] dished head2.93 mm5 mm (4.15)OK
Top head · external[31.6] head, pressure on convex sideallowable 0.11 MPa ≥ design 0.1 MPa5 mmOK
Bottom head · internal[31.3.1] dished head2.93 mm5 mm (4.15)OK
Bottom head · external[31.6] head, pressure on convex sideallowable 0.11 MPa ≥ design 0.1 MPa5 mmOK
Nozzle N1 reinforcement (3S · 316L · top, ID 150 · thickness 10)[34.8] reinforcement of openings in headsrequired area 438.9 mm²effective area 446.2 mm²OK
F-manhole_TOP_Loose_flange (top head)[35.1] pipe flange for nozzles36.4 mm40 mmOK
F-manhole_BTM_Loose_flange (shell)[35.1] pipe flange for nozzles31.4 mm32 mmOK
Sight glass[34.5] sight glass thickness7.60 mm12 mmOK

BB · Jacketed (inner external pressure 0.6 MPa = jacket 0.5 + vacuum 0.1)

PartClauseRequiredUsedResult
Inner shell · internal[30.1.1] cylindrical shell2.00 mm15 mm (14.75)OK
Inner shell · external[30.3] · [Fig. 30.5]allowable 0.77 MPa ≥ design 0.6 MPa15 mmOK
Top head · internal[31.3.1] dished head2.93 mm5 mm (4.15)OK
Top head · external[31.6] head, pressure on convex sideallowable 0.11 MPa ≥ design 0.1 MPa5 mmOK
Bottom head · internal[31.3.1] dished head2.93 mm18 mm (15.77)OK
Bottom head · external[31.6] head, pressure on convex sideallowable 0.62 MPa ≥ design 0.6 MPa18 mmOK
Jacket shell · internal (A240-304)[30.1.1] cylindrical shell3.39 mm4 mm (3.75)OK
Jacket head · internal (A240-304)[31.3.1] dished head4.95 mm6 mm (5.09)OK
Jacket closure (flat plate)[31.16.4.6] jacket closure design15.58 mm18 mmOK
Closure sleeve for nozzle through the jacket (OD 360, cylinder under jacket pressure as external pressure)[30.3] · [Fig. 30.5]allowable 2.50 MPa ≥ design 0.5 MPa8 mmOK
Nozzle N1 reinforcement (3S · 316L · top, ID 90 · thickness 6)[34.8] reinforcement of openings in headsrequired area 263.3 mm²effective area 271.9 mm²OK
Sight glass (2)[34.5] sight glass thickness6.30 mm · 6.33 mm12 mm · 12 mmOK

In B the bottom head sits inside the jacket and is checked at 0.6 MPa external pressure, while the top head is outside the jacket and is checked at 0.1 MPa vacuum — which is why their thicknesses differ. The jacket closure is checked for thickness and for jacket width (40 mm ≤ allowable 129.66 mm).

Figures in the tables are from the calculation pages of the report. The summary sheet shows three decimal places; the calculation pages round to two (e.g. allowable external pressure A shell 0.170 · heads 0.114, B shell 0.768 · top head 0.114 · bottom head 0.615).

External pressure: approximate cross-check of chart readings (not a precise verification)

Values read by eye from the chart and values from a published approximate formula differ by about 10%. This comparison is an approximate check that the report values are in a sensible range — it is not a precise verification. Both values exceed the 0.1 MPa external design pressure, so the result is the same.

Sample A shell (used thickness 6 mm, 5.75 mm after tolerance, external design pressure 0.1 MPa) — report values as printed:

Report (Notice chart reading)Approximate formula
Do / ta · L / Do235.9 · 1.26same
A0.000310.000291
B (316L, 120 °C)30.2 MPa27.0 MPa
Allowable external pressure Pa = 4B / (3·Do/ta)0.17 MPa0.153 MPa
Result (≥ 0.1 MPa)OKOK

Approximate formula used (published): the Windenburg–Trilling approximation for elastic buckling of short cylinders, A ≈ 1.30·(t/Do)1.5 / (L/Do − 0.45·(t/Do)0.5), and B = A·E/2 in the elastic part of the chart (E = 185.8 GPa, read from the elastic line of the chart in the report).

Assumptions and limits

Scope of this sample and of VC calculations

Not calculated

Good to know

Download the report PDFs

Some pages omitted: the material comparison pages, which quote material standard names, were left out of the export. Every page is marked as a sample.

Try it with your own conditions

A report in the same format is produced from your own conditions (type, capacity, pressure, temperature).

AUTONEST VC — install and trial →

This page and the PDFs are examples built on hypothetical conditions and are not for actual design or inspection submission. Figures are copied from the reports AUTONEST VC produced for these conditions; the designer reviews and approves calculation results, and the inspection body decides whether a vessel is subject to inspection and gives the final judgement of conformity.